Displaying test cases 20326 - 20350 of 45437 in total
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 14 Control flow: if(globalFive==5) and if(globalFive!=5)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 13 Control flow: if(GLOBAL_CONST_FIVE==5) and if(GLOBAL_CON...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 12 Control flow: if(globalReturnsTrueOrFalse())
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 11 Control flow: if(globalReturnsTrue()) and if(globalRetur...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 10 Control flow: if(globalTrue) and if(globalFalse)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 09 Control flow: if(GLOBAL_CONST_TRUE) and if(GLOBAL_CONST_...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 08 Control flow: if(staticReturnsTrue()) and if(staticRetur...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 07 Control flow: if(staticFive==5) and if(staticFive!=5)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 06 Control flow: if(STATIC_CONST_FIVE==5) and if(STATIC_CON...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 05 Control flow: if(staticTrue) and if(staticFalse)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 04 Control flow: if(STATIC_CONST_TRUE) and if(STATIC_CONST_...
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 03 Control flow: if(5==5) and if(5!=5)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 02 Control flow: if(1) and if(0)
-
CWE: 690 Unchecked Return Value To NULL Pointer BadSource: calloc Allocate data using calloc() Sinks: GoodSink: Check to see if the data allocation failed and if not, use data BadSink : Dont check for NULL and use data Flow Variant: 01 Baseline
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 18 Control flow: goto statements
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 17 Control flow: for loops
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 16 Control flow: while(1)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 15 Control flow: switch(6)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 14 Control flow: if(globalFive==5) and if(globalFive!=5)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 13 Control flow: if(GLOBAL_CONST_FIVE==5) and if(GLOBAL_CONST_FIVE!=5)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 12 Control flow: if(globalReturnsTrueOrFalse())
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 11 Control flow: if(globalReturnsTrue()) and if(globalReturnsFalse())
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 10 Control flow: if(globalTrue) and if(globalFalse)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 09 Control flow: if(GLOBAL_CONST_TRUE) and if(GLOBAL_CONST_FALSE)
-
CWE: 688 Function Call With Incorrect Variable or Reference as Argument Sinks: GoodSink: Use the correct format to print a string BadSink : Use a string format to print an int Flow Variant: 08 Control flow: if(staticReturnsTrue()) and if(staticReturnsFalse())