Deprecated test suite
Juliet Java 1.0 with extra support Test suite #69
DownloadDescription
This is a collection of test cases in the Java language. It contains examples for 106 different CWEs. NOTE: This package contains only individual test cases. We recommend to download the full test suite at the top of the "Test Suite" page. All documents related to the Juliet Test Suite can be found at the documents page
Displaying test cases 9926 - 9950 of 14184 in total
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 11 Control flow: if(IO.static_returns_t()) and if(IO.static_returns_f())
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 12 Control flow: if(IO.static_returns_t_or_f())
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 13 Control flow: if(IO.static_final_five==5) and if(IO.static_final_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 14 Control flow: if(IO.static_five==5) and if(IO.static_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 15 Control flow: switch(7)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 16 Control flow: while(true) and while(local_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 17 Control flow: for loops
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: double2float GoodSink: check for conversion error BadSink : explicit cast Flow Variant: 19 Control flow: Dead code after an if(true) return
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 01 Baseline
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 02 Control flow: if(true) and if(false)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 03 Control flow: if(5==5) and if(5!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 04 Control flow: if(private_final_t) and if(private_final_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 05 Control flow: if(private_t) and if(private_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 06 Control flow: if(private_final_five==5) and if(private_final_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 07 Control flow: if(private_five==5) and if(private_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 08 Control flow: if(private_returns_t()) and if(private_returns_f())
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 09 Control flow: if(IO.static_final_t) and if(IO.static_final_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 10 Control flow: if(IO.static_t) and if(IO.static_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 11 Control flow: if(IO.static_returns_t()) and if(IO.static_returns_f())
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 12 Control flow: if(IO.static_returns_t_or_f())
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 13 Control flow: if(IO.static_final_five==5) and if(IO.static_final_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 14 Control flow: if(IO.static_five==5) and if(IO.static_five!=5)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 15 Control flow: switch(7)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 16 Control flow: while(true) and while(local_f)
-
CWE: 681 Incorrect Conversion between Numeric Types Sinks: float2int GoodSink: check value before conversion BadSink : conversion may be unsafe Flow Variant: 17 Control flow: for loops