Deprecated test suite
Juliet C/C++ 1.2 with extra support Test suite #86
DownloadDescription
This is a collection of test cases in the C/C++ language. It contains examples for 118 different CWEs. NOTE: This package contains only individual test cases. We recommend to download the full test suite at the top of the "Test Suite" page. All documents related to the Juliet Test Suite can be found at the documents page
Displaying test cases 37176 - 37200 of 61387 in total
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 18 Control flow: goto statements
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 21 Control flow: Flow controlled by value of a static global variable. All functions contained in one file.
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 22 Control flow: Flow controlled by value of a global variable. Sink functions are in a separate file from sources.
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 33 Data flow: use of a C++ reference to data within the same function
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 43 Data flow: data flows using a C++ reference from one function to another in the same source file
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 72 Data flow: data passed in a vector from one function to another in different source files
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 73 Data flow: data passed in a list from one function to another in different source files
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 74 Data flow: data passed in a map from one function to another in different source files
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 81 Data flow: data passed in a parameter to an virtual method called via a reference
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 82 Data flow: data passed in a parameter to an virtual method called via a pointer
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 83 Data flow: data passed to class constructor and destructor by declaring the class object on the stack
-
CWE: 563 Unused Variable BadSource: Initialize data Sinks: GoodSink: Initialize, then use data BadSink : Do nothing Flow Variant: 84 Data flow: data passed to class constructor and destructor by declaring the class object on the heap and deleting it after use
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 01 Baseline
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 02 Control flow: if(1) and if(0)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 03 Control flow: if(5==5) and if(5!=5)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 04 Control flow: if(STATIC_CONST_TRUE) and if(STATIC_CONST_FALSE)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 05 Control flow: if(staticTrue) and if(staticFalse)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 06 Control flow: if(STATIC_CONST_FIVE==5) and if(STATIC_CONST_FIVE!=5)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 07 Control flow: if(staticFive==5) and if(staticFive!=5)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 08 Control flow: if(staticReturnsTrue()) and if(staticReturnsFalse())
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 09 Control flow: if(GLOBAL_CONST_TRUE) and if(GLOBAL_CONST_FALSE)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 10 Control flow: if(globalTrue) and if(globalFalse)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 11 Control flow: if(globalReturnsTrue()) and if(globalReturnsFalse())
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 13 Control flow: if(GLOBAL_CONST_FIVE==5) and if(GLOBAL_CONST_FIVE!=5)
-
CWE: 563 Unused Variable BadSource: Initialize data GoodSource: Initialize and use data Sinks: GoodSink: Use data BadSink : Initialize and use data Flow Variant: 14 Control flow: if(globalFive==5) and if(globalFive!=5)