Deprecated test suite
Juliet C/C++ 1.2 with extra support Test suite #86
DownloadDescription
This is a collection of test cases in the C/C++ language. It contains examples for 118 different CWEs. NOTE: This package contains only individual test cases. We recommend to download the full test suite at the top of the "Test Suite" page. All documents related to the Juliet Test Suite can be found at the documents page
Displaying test cases 53051 - 53075 of 61387 in total
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 04 Control flow: if(STATIC_CONST_TRUE) and if(STATIC_CONST_FALSE)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 05 Control flow: if(staticTrue) and if(staticFalse)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 06 Control flow: if(STATIC_CONST_FIVE==5) and if(STATIC_CONST_FIVE!=5)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 07 Control flow: if(staticFive==5) and if(staticFive!=5)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 08 Control flow: if(staticReturnsTrue()) and if(staticReturnsFalse())
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 09 Control flow: if(GLOBAL_CONST_TRUE) and if(GLOBAL_CONST_FALSE)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 10 Control flow: if(globalTrue) and if(globalFalse)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 11 Control flow: if(globalReturnsTrue()) and if(globalReturnsFalse())
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 12 Control flow: if(globalReturnsTrueOrFalse())
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 13 Control flow: if(GLOBAL_CONST_FIVE==5) and if(GLOBAL_CONST_FIVE!=5)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 14 Control flow: if(globalFive==5) and if(globalFive!=5)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 15 Control flow: switch(6)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 16 Control flow: while(1)
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 17 Control flow: for loops
-
CWE: 416 Use After Free Sinks: GoodSink: Use a block of memory returned from a function BadSink : Use a block of memory returned from a function after it has been freed Flow Variant: 18 Control flow: goto statements
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 01 Baseline
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 02 Control flow: if(1) and if(0)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 03 Control flow: if(5==5) and if(5!=5)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 04 Control flow: if(STATIC_CONST_TRUE) and if(STATIC_CONST_FALSE)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 05 Control flow: if(staticTrue) and if(staticFalse)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 06 Control flow: if(STATIC_CONST_FIVE==5) and if(STATIC_CONST_FIVE!=5)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 07 Control flow: if(staticFive==5) and if(staticFive!=5)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 08 Control flow: if(staticReturnsTrue()) and if(staticReturnsFalse())
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 09 Control flow: if(GLOBAL_CONST_TRUE) and if(GLOBAL_CONST_FALSE)
-
CWE: 457 Use of Uninitialized Variable BadSource: no_init Dont initialize data GoodSource: Initialize data Sinks: use GoodSink: Initialize then use data BadSink : Use data Flow Variant: 10 Control flow: if(globalTrue) and if(globalFalse)