Juliet C/C++ 1.0 Test suite #25
DownloadDescription
A collection of test cases in the C/C++ language. It contains examples for 116 different CWEs. This software is not subject to copyright protection and is in the public domain. NIST assumes no responsibility whatsoever for its use by other parties, and makes no guaranties, expressed or implied, about its quality, reliability, or any other characteristic. All documents related to the Juliet Test Suite can be found at the documents page.
Documentation
Displaying test cases 17526 - 17550 of 45309 in total
-
CWE: 191 Integer Underflow BadSource: fscanf Read data from the console using fscanf() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 65 Data/control flow: data passed as an argument fr...
-
CWE: 191 Integer Underflow BadSource: fscanf Read data from the console using fscanf() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 66 Data flow: data passed in an array from one func...
-
CWE: 191 Integer Underflow BadSource: fscanf Read data from the console using fscanf() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 67 Data flow: data passed in a struct from one func...
-
CWE: 191 Integer Underflow BadSource: fscanf Read data from the console using fscanf() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 68 Data flow: data passed as a global variable from...
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 01 Baseline
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 02 Control flow: if(1) and if(0)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 03 Control flow: if(5==5) and if(5!=5)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 04 Control flow: if(static_const_t) and if(static_const_f)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 05 Control flow: if(static_t) and if(static_f)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 06 Control flow: if(static_const_five==5) and if(static_const_five...
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 07 Control flow: if(static_five==5) and if(static_five!=5)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 08 Control flow: if(static_returns_t()) and if(static_returns_f())
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 09 Control flow: if(global_const_t) and if(global_const_f)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 10 Control flow: if(global_t) and if(global_f)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 11 Control flow: if(global_returns_t()) and if(global_returns_f())
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 12 Control flow: if(global_returns_t_or_f())
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 13 Control flow: if(global_const_five==5) and if(global_const_five...
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 14 Control flow: if(global_five==5) and if(global_five!=5)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 15 Control flow: switch(6) and switch(7)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 16 Control flow: while(1) and while(0)
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 17 Control flow: for loops
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 18 Control flow: goto statements
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 19 Control flow: Dead code after a return
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 31 Data flow using a copy of data within the same function
-
CWE: 191 Integer Underflow BadSource: rand Set data to result of rand() GoodSource: Small, non-zero Sinks: GoodSink: Ensure there is no underflow before performing the subtraction BadSink : Subtract 1 from data Flow Variant: 32 Data flow using two pointers to the same value within the same ...